Features
- 4″ Foam-In-Placed Urethane Insulation
- S/S Heavy Duty Finish
- 36″ x 78″ Door with 3 Hinges, View Window & Kickplates
- Door Switch Fan Motor Activation/Deactivation
- Digital Controller
- Diagnostic Software
- Food Probe
Benefits
- Safely & consistently cools down foods from temperatures of 140°F to 40°F
- It helps eliminate food contamination by cooling it through the danger zone in a timely manner
- Reduces microbial activity
- Provides accurate internal temperature readings
- Improves performance in production kitchens by reducing the wait time necessary for foods to cool down
- Ensures compliance of strict food safety regulations
Options
- Temperature Alarms
- Windows
- Prison Security Package
- Alternate Finishes
Description
Blast Chiller Data
Model No. | Food Cart Qty | Max Load LBS/Cycle | Exterior Cabinet DIMS | Door Opening | Volts | Phase | HZ | Total AMPS | ||||
W | D | H | W | H | MCA | MOPS | ||||||
ABC - 10 | 1 | 250 | 6'2" | 4'3" | 8'4" | 36" | 78" | 115/208 | 3 | 60 | 15 | 20 |
ABC - 20 | 2 | 500 | 6'2" | 6'4" | 8'4" | 36" | 78" | 115/208 | 3 | 60 | 25 | 30 |
Condensing Unit Data
AIr Cooled | ||||||||||
Model No. | Requires Net BTU/HR @10°F SST | Water GPM | Condensing Unit Model | Voltage | RLA | LRA | AMP | MCA | MOPD | |
ABC - 10 | Chilling | 35,360 | N/A | RZM055E3 | 208V/3PH | 19.2 | 123.0 | 22.7 | 28.3 | 30.0 |
Holding | 6,600 | N/A | RHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.7 | 5.9 | 15.0 | |
ABC - 10 | Chilling | 35,360 | N/A | RZM055D3 | 460V/3PH | 8.7 | 62.0 | 10.6 | 13.2 | 15.0 |
Holding | 6,600 | N/A | RHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.7 | 5.9 | 15.0 | |
ABC - 20 | Chilling | 81,380 | N/A | RZM100E3 | 208V/3PH | 52.9 | 248.0 | 58.3 | 72.9 | 80.0 |
Holding | 6,600 | N/A | RHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.7 | 5.9 | 15.0 | |
ABC - 20 | Chilling | 81,380 | N/A | RZM100D3 | 460V/3PH | 25.0 | 150.0 | 28.8 | 36.0 | 40.0 |
Holding | 6,600 | N/A | RHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.7 | 5.9 | 15.0 |
Condensing Unit Data
Water Cooled | ||||||||||
Model No. | Requires Net BTU/HR @10°F SST | Water GPM | Condensing Unit Model | Voltage | RLA | LRA | AMP | MCA | MOPD | |
ABC - 10 | Chilling | 35,0000 | 8.5 | WZM055E3 | 208V/3PH | 19.2 | 123.0 | 19.2 | 24.0 | 30.0 |
Holding | 6,800 | 8.2 | WHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.2 | 5.2 | 15.0 | |
ABC - 10 | Chilling | 35,000 | 8.5 | WZM055D3 | 460V/3PH | 8.7 | 62.0 | 8.7 | 10.9 | 15.0 |
Holding | 6,800 | 2.0 | WHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.2 | 5.2 | 15.0 | |
ABC - 20 | Chilling | 82,000 | 20.0 | WZM100E3 | 208V/3PH | 40.0 | 212.0 | 40.0 | 50.0 | 60.0 |
Holding | 6,800 | 2.0 | WHM010E3 | 208V/3PH | 4.2 | 31.0 | 4.2 | 5.2 | 15.0 | |
ABC - 20 | Chilling | 82,000 | 20.0 | WZM100D3 | 460V/3PH | 20.0 | 106.0 | 20.0 | 25.0 | 30.0 |